Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Thermosensation01:43

Thermosensation

33.3K
Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
33.3K
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

1.5K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.5K
Assessing Body Temperature - Axilla01:14

Assessing Body Temperature - Axilla

953
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
953
Sensory Functions of the Skin01:16

Sensory Functions of the Skin

7.3K
The skin is the largest organ of the human body and plays a crucial role in our sensory perception. It contains a vast network of sensory receptors that contribute to the skin's protective function by perceiving physical, biological, and environmental cues and generating relevant responses.
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...
7.3K
Assessing Body Temperature - Tympanic membrane01:14

Assessing Body Temperature - Tympanic membrane

960
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
960
Assessing Body Temperature - Temporal Artery01:19

Assessing Body Temperature - Temporal Artery

876
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.  
Step 3: Assess the patient's...
876

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Amphibious passive adaptation in untethered soft robots.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Preserving Microstructure Enhances Cohesion and Mechanical Performance in <i>Spirulina</i>-Based 3D-Printed Biomaterials.

ACS applied engineering materials·2026
Same author

Deformation Driven Suction Cups: A Mechanics-Based Approach to Wearable Electronics.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Self-supervised AI for decoding and designing disordered metamaterials.

Science advances·2026
Same author

3D nanolithography with metalens arrays and spatially adaptive illumination.

Nature·2025
Same author

Rigidity Criteria for Chainmail Consisting of Tessellations of Torus Knots.

Physical review letters·2025

Related Experiment Video

Updated: Dec 1, 2025

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
08:50

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management

Published on: September 2, 2015

9.2K

Biomimetic temperature-sensing layer for artificial skins.

Raffaele Di Giacomo1, Luca Bonanomi1,2, Vincenzo Costanza1,2

  • 1Department of Mechanical and Process Engineering (D-MAVT), Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.

Science Robotics
|November 7, 2020
PubMed
Summary
This summary is machine-generated.

Researchers developed pectin films that mimic pit viper membranes for highly sensitive temperature detection. These advanced artificial membranes offer superior performance for robotics and bioengineering applications.

More Related Videos

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
06:08

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging

Published on: May 5, 2011

17.1K
Author Spotlight: Enhancing Skin Model Diversity with Cost-Effective 3D Cellular Models
08:32

Author Spotlight: Enhancing Skin Model Diversity with Cost-Effective 3D Cellular Models

Published on: October 20, 2023

3.6K

Related Experiment Videos

Last Updated: Dec 1, 2025

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
08:50

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management

Published on: September 2, 2015

9.2K
Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
06:08

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging

Published on: May 5, 2011

17.1K
Author Spotlight: Enhancing Skin Model Diversity with Cost-Effective 3D Cellular Models
08:32

Author Spotlight: Enhancing Skin Model Diversity with Cost-Effective 3D Cellular Models

Published on: October 20, 2023

3.6K

Area of Science:

  • Materials Science
  • Biomimetics
  • Sensor Technology

Background:

  • Artificial temperature-sensitive membranes are crucial for advanced robotics and bioengineering, particularly in prosthetics.
  • Existing flexible sensors have limitations in temperature sensitivity range and responsivity.
  • Biological systems, like pit viper pit membranes, exhibit exceptional thermal sensing capabilities.

Purpose of the Study:

  • To develop a novel artificial membrane with high temperature sensitivity and responsivity across a wide temperature range.
  • To mimic the natural thermal sensing mechanism found in pit viper pit membranes.
  • To create a material suitable for integration into artificial skin platforms.

Main Methods:

  • Investigated pectin films as a biomimetic material for thermal sensing.
  • Characterized the temperature sensitivity and responsivity of pectin films.
  • Compared the performance of pectin films to natural pit viper membranes and existing artificial sensors.

Main Results:

  • Pectin films demonstrated a sensitivity of at least 10 millikelvin within a wide 45 kelvin temperature range.
  • The films exhibited high responsivity, comparable to the record performance of pit viper membranes.
  • Pectin films successfully detected warm bodies at a distance.

Conclusions:

  • Pectin films effectively mimic the thermal sensing mechanism of pit viper membranes, achieving superior performance.
  • This biomimetic material offers a versatile solution for enhancing temperature sensitivity in artificial skin and other applications.
  • The developed pectin-based membranes represent a significant advancement in artificial thermal sensing technology.