Tronco-conical locking plate in distal radius fractures
Related Experiment Video
Updated: Dec 1, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Alessio Maiello1, Fabrizio Rivera1, Pietro Maniscalco2
1Orthopaedic and Trauma Department, S.S. Annunziata Hospital, Savigliano (CN), Italy.
Introduction:
Volar locked plates represent the most popular fixation technique for distal radius fracture (DRF). However, threaded screw-hole angular stability mechanism has some issues. The purpose of our study is to evaluate clinical and radiological outcome of a tronco-conical locking mechanism for volar plating of DRF.
Materials And Methods:
Eighty patients with DRF treated with tronco-conical locking volar plates between May 2013 to December 2017 in two institutions were collected. We analysed clinical and radiological outcomes and peri-operative complications, like loss of reduction, fragment displacement, deformation or implant-related problems and surgical and other general complications.
Results:
78 patients were available for at final follow-up. The average follow-up period was 11.4 months (range, 6-18 months). All fractures healed within three months. Five cases of final reductions were defined unsatisfying. According to Gartland and Werley's scoring system at final follow up, 36 patients had excellent results, 40 patients had good results, one patient had fair and one patient had poor results. Five complications were observed. No complications were observed during surgical plate removal.
Conclusion:
Complications found in our study are not related to tronco-conical locking mechanism and are like those found in the literature. Further studies are needed to evaluate functional results or radiographic parameters of this new type of angular stability mechanism. Tronco-conical locking plate is an attractive alternative threaded screw-hole angular stability mechanism.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...