Voltammetric pH sensor based on electrochemically modified pseudo-graphite
Haoyu Zhu1, Tanim Hassan, Humayun Kabir
1University of Idaho, Department of Chemistry, 875 Perimeter Dr., MS 2343, Moscow, ID 83844, USA. ifcheng@uidaho.edu.
Abstract:
A nanocrystalline graphite-like amorphous carbon (graphite from the University of Idaho thermolyzed asphalt reaction, GUITAR) shares morphological features with classical graphites, including basal and edge planes (BP, EP). However, unlike graphites and other sp2-hybridized carbons, GUITAR has fast heterogenous electron transfer (HET) across its basal planes, and resistance to corrosion similar to sp3-C and boron-doped diamond electrodes. In this contribution, quinoid modified BP-GUITAR (q-GUITAR) is examined as a sensor for pH determination. This modification is performed by applying 2.0 V (vs. Ag/AgCl) for 150 seconds followed by 15 cyclic voltammetric scans from -0.7 to 1.0 V at 50 mV s-1 in 1.0 M H2SO4. The quinoid surface coverage of q-GUITAR is 1.35 × 10-9 mol cm-2, as measured by cyclic voltammetry. X-ray photoelectron spectroscopy analysis also confirms the high surface coverage. The quinoid surface concentration ranks highest in literature when compared with other basal plane graphitic materials. This yields a sensor that responds through a square wave voltammetric reduction peak shift of 63.3 mV per pH over a pH range from 0 to 11. The response on q-GUITAR is stable for >20 measurements and no surface re-activation is required between the measurements. The common interferents, Na+, K+ and dissolved oxygen, have no effect on the response of the q-GUITAR-based pH sensor.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
08:19Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetric Techniques: Pulse Voltammetry
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Voltammetric Techniques: Cyclic Voltammetry
Potentiometry: Membrane Electrodes