Related Experiment Video
Updated: Dec 1, 2025

Measuring Phosphorus Release in Laboratory Microcosms for Water Quality Assessment
Published on: July 22, 2019
Response of palladium in receiving water bodies to rainfall-runoff
Fangfang Ding1, Yuyan Liu2, Zucheng Wang3
1College of Geography and Environmental Science, Hainan Normal University, Haikou, 571158, Hainan, China.
Abstract:
Palladium (Pd) is widely used in automotive catalytic converters to reduce toxic gas emissions. The input of Pd in the rainfall-runoff is an important contributing factor to the accumulation of Pd in receiving water bodies. In this study, the Meishe River in Haikou, Hainan Province, China, was used as the research area, and palladium (Pd) was selected as the target pollutant. This study explored the response of Pd in the receiving water body to rainfall-runoff and to analyze the influencing factors. The results showed that the dissolved Pd concentration in the receiving water body had a corresponding relationship with that in rainfall-runoff. The response of suspended Pd in the receiving water body to rainfall-runoff was closely related to the location of the drainage outlet. Compared with that of suspended Pd, the response of dissolved Pd in the receiving water body to that in the rainfall-runoff was more obvious. Seven meters downstream from the outfall was the most sensitive response distance of dissolved Pd in receiving water bodies to rainfall-runoff, and the response time was approximately 0-10 min. The suspended Pd at 3 m downstream from the outfall also had a certain response to the rainfall-runoff, and the response time was approximately 15-25 min. The response time of the suspended Pd in the receiving water body depended largely on the first flush ability of the runoff. There was a moderately positive correlation between the dissolved Pd and Cl- in the receiving water body (r = 0.687; p < 0.05). The effects of pH, Eh, and total suspended solids (TSS) on suspended Pd were reduced in the response process of the receiving water body. The synergistic effect of multiple factors increased the uncertainty of the Pd response.
More Related Videos
06:58Photodeposition of Pd onto Colloidal Au Nanorods by Surface Plasmon Excitation
Published on: August 15, 2019
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Responses to Drought and Flooding
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation and Co-precipitation
Types of Coprecipitation
Sometimes, ions in a crystal lattice can undergo isomorphous replacement by inclusions of similar charge and size. For...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: