Effect of ablation behavior on the matrix effect in nanosecond laser ablation inductively coupled plasma mass
Abstract:
To investigate the effect of ablation behavior on the matrix effect, nanosecond laser ablation inductively coupled plasma mass spectrometry is used to analyze variations in element signal intensities of NIST 610 and GSE-1G standard samples with different laser fluence. Scanning electron microscopy and super depth-of-field microscopy are used to capture the morphology of the ablation crater and obtain depth information, respectively. A pump-probe shadowgraph is used to record the dynamic process of plasma plume evolution during sample ablation. Experimental results show that the proportion of refractory elements to volatile elements in the ablation materials with two different matrices increases with an increase in laser fluence. For the GSE-1G matrix, this range of increase is relatively small, and the signal loss of refractory elements occurs at a higher laser fluence. Combined with the morphology of the ablation crater and evolution of the plasma plume, this potential cause is related to the plasma shielding, which is beneficial to form and deposit large particles, resulting in the loss of refractory elements at high energy fluence.
More Related Videos
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....