Related Experiment Video
Updated: Nov 30, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention
Ronald S Arellano1, Kai Yang2, Madan M Rehani2
1Radiology Department, Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA. rarellano@mgh.harvard.edu.
Objective:
To identify a patient cohort who received ≥ 100 mSv during a single computed tomography (CT)-guided intervention and analyze clinical information.
Materials And Methods:
Using the dose-tracking platform Radimetrics that collects data from all CT scanners in a single hospital, a patient-level search was performed retrospectively by setting a threshold effective dose (E) of 100 mSv for the period from January 2013 to December 2017. Patients who received ≥ 100 mSv in a single day during a single CT-guided intervention were then identified. Procedure types were identified, and medical records were reviewed up to January 2020 to identify patients who developed short- and/or medium-term (up to 8 years) medical consequences.
Results:
Of 8952 patients with 100 mSv+, there were 33 patients who underwent 37 CT-guided interventions each resulting in ≥ 100 mSv. Procedures included ablations (15), myelograms (8), drainages (7), biopsies (6), and other (1). The dose for individual procedures was 100.2 to 235.5 mSv with mean and median of 125.7 mSv and 111.8 mSv, respectively. Six patients (18 %) were less than 50 years of age. During the study period of 0.2 to 7 years, there were no deterministic or stochastic consequences identified in this study cohort.
Conclusions:
While infrequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv. Awareness of the possibility of such high doses and potential for long-term deleterious effects, especially in younger patients, and consideration of alternative imaging guidance and/or further dose optimization should be strongly considered whenever feasible.
Key Points:
• Although not so frequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv • Procedures with potential for high dose includes ablations, myelograms, drainages, and biopsies.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT

