Objectives:
This study was conducted to assess the impact of tube voltage on ambient dose during intraoral radiography, specifically remnant-beam transmission and scattered radiation.
Methods And Materials:
Remnant-beam and scattered radiation doses were recorded using a phantom at tube voltages of 60, 63, 66 and 70 kV. Mathematical equations depicting their relations were then formulated, and reference values were calculated at the various voltages tested. Total ambient doses per exposure at 60 kV and at 70 kV were compared.
Results:
Both remnant-beam transmission and scattered radiation increased ~40% by increasing tube voltage from 60 kV to 70 kV, and the relation was linear. A remnant beam transmission reference value of 7.5% was established at 70 kV, as well as a conversion factor of 0.035 µSv/mAs at 1 m for scattered radiation at 60 kV. Given longer exposure times at 60 kV, total ambient dose proved higher at 60 kV than at 70 kV.
Conclusion:
Higher tube voltage results in higher remnant-beam transmission and more scattered radiation per workload. The relation is linear in the range between 60kV and 70 kV. Remnant-beam transmission at 70 kV is safely assessed at 7.5%. A conversion factor at 60 kV of 0.035 µSv/mAs at 1 m for the scattered radiation dose can be proposed. Total ambient dose per exposure was higher at 60kV than at 70 kV.
More Related Videos
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan: