Related Experiment Video
Updated: Nov 30, 2025

Potentiodynamic Corrosion Testing
Published on: September 4, 2016
Study to Assess the Rate of Adverse Reaction to Metal Debris in Hip Resurfacing at a Minimum 13-year Follow-up
Graham R Hastie1, Sophie C Collinson1, Adeel Aqil1
1Wigan and Leigh NHS Trust, Wrightington Hospital, Wigan, United Kingdom, WN6 9EP.
Background:
Hip Resurfacing (HR), although reducing in popularity, is still used in the younger male population. Excellent medium-term results have been published; however, the use of metal on metal has reduced with increased awareness of adverse reactions to metal debris (ARMD). ARMD has been shown to often be clinically "silent" following large Head MoM total hip replacement (THR). The purpose of our study was to report the incidence of ARMD following HR with a minimum follow-up of 13 years.
Methods:
We performed a retrospective study of a consecutive series of patients who underwent HR between January 1, 2000 and August 1, 2005. All patients were entered into our hospital MoM hip replacement surveillance program database. Patients were reviewed yearly for symptoms and blood ion levels. Patients had Magnetic Resonance (MR) imaging to assess for ARMD.
Results:
A total of 102 patients with 123 hip replacements were included in the study. Eight hips in 7 patients were revised: two for fracture, one for avascular necrosis, and five for ARMD. A best-case scenario of 109 (93.2%) resurfacings were surviving at 13 years. With regard to the radiological analysis, 34% were found to have ARMD on MR.
Conclusion:
While the implant survivorship in our series is acceptable, we found a high incidence of ARMD. Surgeons and patients with or considering a HR should be aware of the risk of ARMD developing. This allows an informed choice as to the best implant for their personal requirement and informs of the potential modes of failure and need for long-term screening.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022