Inter-rater Reliability of 4-Item Arterial Doppler Waveform Classification System for Description of Arterial Doppler
Rui Zhao1, Damien Lanéelle2,3, Meiying Gao1
1Peking University International Hospital, Haidian, China.
Abstract:
Background: Non-invasive Doppler waveform (DW) analysis is a widely adopted method for detecting and evaluating lower extremity peripheral artery disease (PAD). Previous investigations have reported that broad heterogeneity in the description of Doppler waveforms is reduced by using a classification method. The reliability of arterial Doppler classification, however, is unknown. Purpose: The purpose of this study is to assess the reliability of a 4-category arterial DW classification method among Chinese sonographers. Methods: During a national ultrasound conference in China attendees were invited to classify thirty arterial Doppler waveforms. After viewing a 4-category (triphasic, biphasic, monophasic, and other) arterial Doppler waveform descriptor presentation, attendees were asked to classify 15 continuous wave (CW) and 15 pulsed wave (PW) Doppler waveforms. Their responses were recorded via mobile phone and the reliability of this 4-category classification was estimated by Fleiss' Kappa inter-rater statistical analysis. Results: One hundred and seventy-eight attendees participated in the analysis. The Kappa coefficient of Fleiss (κ) for all attendees was 0.522 (p < 0.005) with 95% confidence interval (CI): 0.520-0.523. The reliability of the waveform descriptor triphasic was the highest (κ = 0.621, p < 0.005), and other was the lowest (κ = 0.341, p < 0.005). Conclusion: The inter-rater reliability of a 4-category arterial Doppler waveform classification by Chinese sonographers is considered weak (κ = 0.522, CI95%: 0.520-0.523, p < 0.005). This study reinforces the importance of assessing DW classification reliability and the development of DW descriptors that are more accurately predictive of clinical hemodynamic events.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation