Related Experiment Video
Updated: Nov 30, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Inorganic oxidizer detection from propellants, pyrotechnics, and homemade explosive powders using gradient elution
Shannon T Krauss1, Thomas P Forbes1, Dillon Jobes2
1National Institute of Standards and Technology, Gaithersburg, MD, USA.
Abstract:
Advancement in rapid targeted chemical analysis of homemade and improvised explosive devices is critical for the identification of explosives-based hazards and threats. Gradient elution moving boundary electrophoresis (GEMBE), a robust electrokinetic separation technique, was employed for the separation and detection of common inorganic oxidizers from frequently encountered fuel-oxidizer mixtures. The GEMBE system incorporated sample and run buffer reservoirs, a short capillary (5 cm), an applied electric field, and a pressure-driven counterflow. GEMBE provided a separation format that allowed for continuous injection of sample, selectivity of analytes, and no sample cleanup or filtration prior to analysis. Nitrate, chlorate, and perchlorate oxidizers were successfully detected from low explosive propellants (e.g., black powders and black powder substitutes), pyrotechnics (e.g., flash powder), and tertiary explosive mixtures (e.g., ammonium nitrate- and potassium chlorate-based fuel-oxidizer mixtures). Separation of these mixtures exhibited detection without interference from a plethora of additional organic and inorganic fuels, enabled single particle analysis, and demonstrated semiquantitative capabilities. The bulk counterflow successfully excluded difficult components from fouling the capillary, yielding estimated limits of detection down to approximately 10 μmol/L. Finally, nitrate was separated and detected from postblast debris collected and directly analyzed from two nitrate-based charges.
More Related Videos
11:44Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Electrophoresis: Overview
There...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...