[Comparison of three medical goggle sterilizing approaches]
Qun Wang1, Junjun Mo1, Fang Huang1
1Central Sterile Supply Department, the First Affiliated Hospital, Zhejiang University School of Medical, Hangzhou 310003, China.
Objective:
To compare three sterilizing methods for reusable medical goggles.
Methods:
A total of 180 medical goggles of the same brand and same model were randomly divided into three groups. In group A the goggles were first soaked with 2000 mg/L chlorine-containing disinfectant and then cleaned manually; goggles in other two groups were sterilized using pre-programmed automatic spray cleaning and disinfection machine, the disinfection program was set to 90 ℃ for 5 min in group B and 70 ℃ for 30 min in group C. The quality of the sterilization was monitored by visual inspection with luminous magnifying glass and residual protein detection assay. User satisfaction on cleanliness of medical goggles, clarity of mirror surface and suitability of elastic bands was investigated with questionnaire survey.
Results:
The qualification rates verified by visual inspection were 82.4%, 84.6%and 98.3%in group A, B and C, respectively, the qualification rate in group C was significantly higher than those in group B and group C (all P<0.05). The qualification rates verified by residual protein detection assay were 96.7%, 100.0%and 100.0%in group A, B and C, respectively (P>0.05). A total of 54 questionnaires were submitted for the survey. The satisfaction rates were 100.0%, 90.7%and 94.4% for cleanliness of medical goggles, clarity of mirror surface and suitability of elastic bands, respectively.
Conclusions:
Machinery sterilization set 70 ℃ for 30 min has better cleaning and sterilizing effects for reusable medical goggles.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...