Modified PID controller for automatic generation control of multi-source interconnected power system using fitness
Amil Daraz1, Suheel Abdullah Malik1, Ihsan Ul Haq1
1Department of Electrical Engineering, Faculty of Engineering and Technology, International Islamic University, Islamabad, Pakistan.
This study introduces an Integral-Proportional Derivative (I-PD) controller optimized using the Fitness Dependent Optimizer (FDO) algorithm for enhanced Automatic Generation Control (AGC) in interconnected power systems. The FDO-I-PD controller significantly improves system stability by reducing overshoot and settling time.
Area of Science:
- Electrical Engineering
- Control Systems Engineering
- Optimization Algorithms
Background:
- Automatic Generation Control (AGC) is crucial for maintaining grid stability in interconnected power systems (IPS).
- Traditional Proportional Integral Derivative (PID) controllers face challenges in optimizing performance across diverse power system configurations.
- Multi-source power systems with varying generation units (gas, hydro, thermal) require advanced control strategies for reliable operation.
Purpose of the Study:
- To develop and optimize a modified Integral-Proportional Derivative (I-PD) controller for AGC in a two-area multi-source IPS.
- To employ the Fitness Dependent Optimizer (FDO) algorithm for tuning the I-PD controller parameters based on multiple performance indices.
- To evaluate the proposed controller's effectiveness and robustness against existing methods and system variations.
Main Methods:
- A novel Integral-Proportional Derivative (I-PD) controller structure was proposed.
- The Fitness Dependent Optimizer (FDO) algorithm was utilized to optimize controller parameters, minimizing Integral of Absolute Error (IAE), Integral of Time multiplied Absolute Error (ITAE), Integral of Time multiplied Square Error (ITSE), and Integral Square Error (ISE).
- Simulations were conducted on a two-area IPS with individual and combined gas, hydro, and reheat thermal units, comparing performance against Differential Evolution (DE-PID) and Teaching Learning Based Optimization (TLBO) hybridized controllers (LUS-PID).
Main Results:
- The proposed FDO-optimized I-PD controller (FDO-I-PD) demonstrated superior performance compared to other controllers.
- Significant improvements were observed in reducing Overshoot (Osh), Settling time (Ts), and Undershoot (Ush).
- The controller's robustness was validated through system parameter variations and load changes.
Conclusions:
- The developed FDO-I-PD controller offers a significant advancement for AGC in multi-source interconnected power systems.
- The FDO algorithm effectively optimizes the I-PD controller for improved transient response and stability.
- The proposed control strategy provides a robust and efficient solution for modern power grid management.
More Related Videos
08:35Interactive and Visualized Online Experimentation System for Engineering Education and Research
Published on: November 24, 2021
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
Related Concept Videos
PID Controller
Load-frequency control
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Control of Power Flow
Fast Decoupled and DC Powerflow