Pressure - flow measurements of pumps used in extracorporeal life support
Federico Rorro1, Lisa Prahl Wittberg1, Fabio Silvio Taccone2
1FLOW, Department of Engineering Mechanics, Royal Institute of Technology (KTH), Stockholm, Sweden.
Abstract:
IntroductionThe blood pump is a central component of the extracorporeal life support (ECLS) circuit. Modern centrifugal and diagonal pumps are mainly used in preference to roller pumps. Compared to roller pumps, centrifugal and diagonal pumps offer lower priming volume, less hemolysis and enable miniaturization of circuits. Drawback is the open design promoting internal recirculation, which influences performance and, in few studies at low flow, may increase risk of coagulation activation and hemolysis. The aim of this work was to provide performance data on available pumps.MethodsManufacturers were asked to lend ECLS consoles and donate pump samples for the study. No financial support was accepted. Missing pumps were bought by the investigators. In a mock-loop, measurements of volume flow and pressures were performed. Pumps were assessed over the operating flow range stated by the manufacturer at different preloads and afterload levels.ResultsEight different ECLS pumps were tested, two available for pediatric use and six for adult use. Six pumps were centrifugal and two were of diagonal design. All were magnetically driven and three were magnetically levitated. Five had impellers with shrouded (covered) design. Water or water-glucose were used as a test fluid and choice of medium is herewith also discussed. Flow-pressure maps for each pump were generated over its operating range. As agreed with manufacturers, no direct comparisons between pumps were made.ConclusionsPerformance curves for blood pumps designed for ECLS use in children and adults were reported and important aspects of design features discussed to support clinicians.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pipe Flowrate Measurement
The orifice meter is a simple,...