Intra tester reliability of sympathetic skin responses in subjects with primary palmar hyperhidrosis
Elham Ghandali1, Seyed Majid Hosseini2, Hamid Reza Moghimi3
1Department of Physiotherapy, School of Rehabilitation, Student Research Committee, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Background:
Primary palmar hyperhidrosis (PPH) is a disorder related to sympathetic dysfunction. Iontophoresis can be used to reduce sweating rate. Sympathetic skin response (SSR) is commonly used to evaluate the sympathetic system. However, scarce evidence exists about the reliability of SSR parameters.
Objective:
To assess the relative and absolute reliability of SSR before and after the application of iontophoresis with aluminum chloride hexahydrate (ACH) gel or tap water in subjects with PPH.
Methods:
Twenty subjects were randomized to receive either iontophoresis with ACH gel or tap water. Three SSRs (amplitude and latency) with 5 s intervals from both hands in both groups were recorded before and after the application of iontophoresis for 30 min. Reliability of amplitude and latency of the SSR was assessed using intraclass correlation coefficient (ICC) with 95% confidence intervals, standard error of measurement (SEM), and minimal detectable change (MDC).
Results:
Amplitudes and latencies of SSR showed good to excellent test-retest reliability for ICC in both groups before iontophoresis. Except for right hand latency which was moderate (0.5-0.75). After iontophoresis, the ACH gel group still showed good to excellent agreement for SSR parameters, while the reliability of SSR parameters in the tap water group was reduced.
Conclusion:
Subjects with PPH showed high intra-rater reliability for SSR parameters which was maintained after ACH gel iontophoresis and decreased after tap water iontophoresis. It seems that media used for iontophoresis or the state of media (gel vs liquid) may affect the reliability of SSR. Further research is recommended.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...