Related Experiment Video
Updated: Nov 28, 2025

Precise Electrochemical Sizing of Individual Electro-Inactive Particles
Published on: August 4, 2023
Synthesis and Characterization of Ru-MOFs on Microelectrode for Trace Mercury Detection
Chenyu Xiong1,2, Yuhao Xu1,2, Chao Bian1,2
1State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
Abstract:
Mercury ions (Hg2+) pollution in the water environment can cause serious harm to human health. Trace Hg2+ detection is of vital importance for environmental monitoring. Herein, we report a novel design of Ru-MOFs modified gold microelectrode for Hg2+ determination. Ru-MOFs are synthesized directly by the cathodic method on gold microelectrode, with the covered area accurately controlled. Cathodic synthesized Ru-MOFs show good conductivity and are suitable to be used as the electrode surface material directly. The synergy of the pre-deposition process and the adsorption process of Ru-MOFs can effectively improves the performance of the sensor. The results show good linearity (R2 = 0.996) from 0.1 ppb to 5 ppb, with a high sensitivity of 0.583 μA ppb-1 mm-2. The limit of detection is found to be 0.08 ppb and the test process is within 6 min. Most importantly, the senor has a good anti-interference ability and the recoveries are satisfactory. This miniature electrochemical sensor has the potential for on-site detection of trace mercury in the field.