Related Experiment Video
Updated: Nov 28, 2025

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Determination of Bromate Ions in Drinking Water by Derivatization with 2-Methyl-2-Butene, Dispersive Liquid-Liquid
Mehdi Nabi1, Sayed Mehdi Ghoreishi1, Mohsen Behpour1
1University of Kashan, Faculty of Chemistry, Department of Analytical Chemistry, Kashan, 8731753153, Iran.
Background:
A simple, rapid, selective and sensitive sample preparation and derivatization method was performed for determination of bromate ions in water by means of dispersive liquid-liquid extraction (DLLE) by gas chromatography-electron capture detection (GC-ECD). This method is based on 2-methyl-2-butene derivatization by bromine produced from bromate ions in acidic medium and extraction by n-hexane.
Objective:
Derivatizing agent: It is cheap and available and it has high efficiency in reaction with Br2. Simplicity: Preparation and extraction process don't need to any specific equipment and procedure is completely simple and fast. Limit of detection: DL is as low as 0.43 µg/L.
Methods:
Various effective factors on the derivatization and extraction efficiency, such as amount of derivatizing agent, volume of extraction solvent, bromide concentration, volume and concentration of sulfuric acid, type and volume of extracting and dispersing solvent, ionic strength, storage time before extraction and ECD makeup-gas flow rate were investigated.
Results:
Under the optimum conditions, the method had a linear calibration curve ranging from 1.0 to 200.0 µg/L for bromate ions with a determination coefficient (R2) of 0.994 and the detection limit was 0.43 µg/L. The recovery percent and relative standard deviation for the determination of 1.0, 5.0 and 50.0 µg/L bromate ion was between 90 and 110%, and 3.0 and 8.0% (n = 3), respectively.
Conclusions:
Finally, the method was successfully applied for the preconcentration and determination of bromate ions in water samples, and satisfactory results were obtained.
Highlights:
(1) Fast, easy, accurate and economical innovative analysis of bromate ions in water and wastewater. (2) Determination of inorganic ion by GC-ECD after derivatization (3) Low detection limit (4) Optimization of different method parameters to obtain accurate results based on requirements of international standards, specifically ISO/IEC 17025.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II