Single Crystal CdSe X-ray Detectors with Ultra-High Sensitivity and Low Detection Limit
Shunyong Wei1, Ming Yang2, Hui Sun3
1Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 610054, China.
Abstract:
CdSe single crystals (SCs), with a relatively high atomic number, large X-ray absorption coefficients, and high carrier mobility, are expected to provide high-performance detection for X-ray. However, the difficulty of growing high-quality CdSe SC has severely limited its application in X-ray detection. In this work, we develop an unconstrained physical gas phase method and in situ annealing process to grow high-quality CdSe SCs under unconstrained conditions. Using this method, CdSe SCs exhibit natural exposure planes, ultrahigh resistivity of 5.43 × 1012 to 1.29 × 1013 Ω cm and high μτ product of 1.3 × 10-2 to 1.5 × 10-2 cm2 V-1. It is also observed that CdSe SC X-ray detectors exhibit a record sensitivity of 2.08 × 105 μC Gyair-1 cm-2 and a low detection limit of 85 nGyair s-1, which are both desired in medical diagnostics. Moreover, those devices with different crystal directions provide anisotropic X-ray detection performance. Our findings pave a new avenue to exploit high-performance CdSe SC X-ray detectors.
More Related Videos
09:23Author Spotlight: Advancing Energy Solutions Using Nanocomposites as Processed Thermoelectric Materials
Published on: May 17, 2024
07:24Quantitative Atomic-Site Analysis of Functional Dopants/Point Defects in Crystalline Materials by Electron-Channeling-Enhanced Microanalysis
Published on: May 10, 2021
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II