Related Experiment Video
Updated: Nov 28, 2025

Application of Laparoscopic Hepatectomy Combined with Intraoperative Microwave Ablation in Colorectal Cancer Liver Metastasis
Published on: March 3, 2023
Contrast-Enhanced Intraoperative Ultrasound Improved Sensitivity and Positive Predictive Value in Colorectal Liver
Wei Liu1, Zhong-Yi Zhang2, Shan-Shan Yin2
1Key Laboratory of Carcinogenesis and Translational Research, Hepatopancreatobiliary Surgery Department I, School of Oncology, Beijing Cancer Hospital and Institute, Peking University, Ministry of Education, Beijing, People's Republic of China.
Background:
The diagnostic accuracy of imaging modalities in colorectal cancer liver metastases (CRLM) has improved in recent years, therefore the role of current imaging techniques needs to be defined.
Objective:
The aim of this study was to assess the diagnostic performance of magnetic resonance imaging, preoperative imaging (magnetic resonance imaging or computed tomography), intraoperative ultrasound, and contrast-enhanced intraoperative ultrasound in the detection of CRLM.
Materials And Methods:
Eligible trials published before 30 March 2020 were identified from the EMBASE, PubMed, Web of Science, and Cochrane Library databases, and descriptive and quantitative data were extracted. Study quality was evaluated for the identified studies and a random-effects model was used to determine the integrated diagnosis estimation. Meta-regression was implemented to explore the possible contributors to heterogeneity.
Results:
Overall, 13 studies were included for analysis, comprising 682 patients with a total of 2303 liver lesions. The pooled sensitivity, specificity, and diagnostic odds ratio of contrast-enhanced intraoperative ultrasound were 0.94 (95% confidence interval [CI] 0.89-0.97), 0.83 (95% CI 0.67-0.92), and 79 (95% CI 32-196), respectively. The overall weighted area under the curve was 0.96 (95% CI 0.94-0.97). In univariate meta-regression analysis, disappearing liver metastasis, contrast agent, and Kupffer phase were the potent sources of heterogeneity; however, in multivariate meta-regression, no definite variable was the source of the study heterogeneity.
Conclusion:
Contrast-enhanced intraoperative ultrasound demonstrated a high sensitivity and specificity for screening CRLM.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
06:39Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
Published on: May 23, 2025