Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Development of retention time indices for comprehensive multidimensional gas chromatography and application to
Nadin Boegelsack1, Court Sandau2, Dena W McMartin3
1Department of Earth and Environmental Sciences, Mount Royal University, 4825 Mount Royal Gate SW, Calgary, AB Canada, T3E 6K6; Department of Civil, Geological and Environmental Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK Canada, S7N 5A9.
Abstract:
In this study, we introduce a simple three-step workflow for a universally applicable RI system, to be used in GC×GC analysis of ignitable liquid residue (ILR) for arson investigations. The proposed RI system applies a combination of two well-established GC RI systems: non-isothermal Kovats (K) index in the first dimension and Lee (L) index in the second dimension. The proposed KLI RI system showed very good correlations when compared with predicted values and existing RI systems (r2 = 0.97 in first dimension, r2 = 0.99 in second dimension) and was valid for a wide range of analyte concentrations and operational settings (coefficient of variance (CV) < 1% in first dimension, < 10% in second dimension). Using the KLI RI, an ILR classification contour map was created to assist with the identification of ILR types within ASTM E1618. The contour map was successfully applied to neat fuels and a fire scene sample, highlighting the application to wildfire investigation. Standardizing the RI process and establishing acceptable error margins allows the exploration and comparison of comprehensive data generated from GC×GC analysis of ILRs regardless of location, time, or system, further enhancing comprehensive and tenable chemometric analyses of samples. Overall, the KLI workflow was inexpensive, quick to apply, and user-friendly with its simple 3-step design.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Chromatographic Methods: Terminology