Cooling Effectiveness of a Data Center Room under Overhead Airflow via Entropy Generation Assessment in Transient
Luis Silva-Llanca1, Marcelo Del Valle2, Alfonso Ortega2
1Instituto de Investigación Multidisciplinario en Ciencia y Tecnología, Departamento de Ingeniería Mecánica, Universidad de La Serena, Benavente 980, La Serena 1720170, Chile.
Abstract:
Forecasting data center cooling demand remains a primary thermal management challenge in an increasingly larger global energy-consuming industry. This paper proposes a dynamic modeling approach to evaluate two different strategies for delivering cold air into a data center room. The common cooling method provides air through perforated floor tiles by means of a centralized distribution system, hindering flow management at the aisle level. We propose an idealized system such that five overhead heat exchangers are located above the aisle and handle the entire server cooling demand. In one case, the overhead heat exchangers force the airflow downwards into the aisle (Overhead Downward Flow (ODF)); in the other case, the flow is forced to move upwards (Overhead Upward Flow (OUF)). A complete fluid dynamic, heat transfer, and thermodynamic analysis is proposed to model the system's thermal performance under both steady state and transient conditions. Inside the servers and heat exchangers, the flow and heat transfer processes are modeled using a set of differential equations solved in MATLAB™ 2017a. This solution is coupled with ANSYS-Fluent™ 18, which computes the three-dimensional velocity, temperature, and turbulence on the Airside. The two approaches proposed (ODF and OUF) are evaluated and compared by estimating their cooling effectiveness and the local Entropy Generation. The latter allows identifying the zones within the room responsible for increasing the inefficiencies (irreversibilities) of the system. Both approaches demonstrated similar performance, with a small advantage shown by OUF. The results of this investigation demonstrated a promising approach of data center on-demand cooling scenarios.
More Related Videos
Related Concept Videos
Entropy
When an ideal gas expands isothermally, the disorder in the gas increases. From the molecular perspective, the gas molecules have more volume to move around in.
Consider an infinitesimal step in the expansion, which...
Entropy
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
General External Flow Characteristics
Entropy and the Second Law of Thermodynamics
The relation between entropy and disorder can be illustrated with the example of the phase change of ice to water. In ice, the molecules are located at specific sites giving a solid state, whereas, in a liquid form, these molecules are much freer to move. The molecular arrangement has therefore become more randomized. Although the change in average...
Mechanism of heat transfer