Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
A Combination MAI and MALDI Vacuum Source Operational from Atmospheric Pressure for Fast, Robust, and Sensitive
Khoa Hoang1, Sarah Trimpin1,2, Charles N McEwen1,3
1MS, LLC, Hockessin, Delaware 19707, United States.
Abstract:
Previously, vacuum matrix-assisted ionization (vMAI) was employed with matrix/analyte sample introduction into the vacuum of a mass spectrometer on a probe sample introduction device. Low attomole detection was achieved, while no carryover was observed even for concentrated samples. Here, we report a new vacuum ionization source designed to duplicate the sensitivity and robustness of probe device while providing fast multisample introduction to vacuum and rapid sequential ionization. Exposure of a sample to the vacuum of the mass spectrometer provides spontaneous ionization of volatile as well as nonvolatile analytes without the need for external energy input. However, the novel source design described herein, in addition to vMAI, can employ a laser to obtain vacuum matrix-assisted laser desorption/ionization (vMALDI). In particular, ionization by vMAI or vMALDI is achieved by using the appropriate matrix. Switching between ionization modes is accomplished in a few seconds. We present results demonstrating the utility of the two ionization methods in combination to improve the molecular analyses of sample composition. In both ionization modes, multiple samples can be sequentially and rapidly acquired to increase throughput in MS. With the prototype source, samples were acquired in as little as 1 s per sample. Exchanging multisample plates can be accomplished in as little as 2 s, suggesting low-cost high-throughput automation when properly developed.
More Related Videos
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Analyzers: Overview