Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Instrument Calibration01:12

Instrument Calibration

536
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
536

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Mavacamten shows broad benefit in human and mouse models of MYBPC3-related hypertrophic cardiomyopathy.

Nature cardiovascular research·2026
Same author

Unveiling the procoagulant state in Alzheimer's disease: A novel PET imaging strategy.

Alzheimer's & dementia : the journal of the Alzheimer's Association·2026
Same author

Chd4 and ThPOK cooperate to preserve structural and electrophysiological integrity of the adult heart through Sprr1a repression.

The FEBS journal·2026
Same author

Clinical Feasibility Studies and Potential Applications of Cone-Beam Computed Tomography Integrated in Multimodality X-Ray System for Small Animals.

Animals : an open access journal from MDPI·2026
Same author

Recurrent intermittent hyponatremia: A new experimental model.

PloS one·2026
Same author

Biomarkers.

Alzheimer's & dementia : the journal of the Alzheimer's Association·2025

Related Experiment Video

Updated: Nov 27, 2025

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

11.5K

Optimization of a calibration phantom for quantitative radiography.

Cristobal Martinez1,2, Claudia de Molina1, Manuel Desco1,2,3,4

  • 1Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid, Spain.

Medical Physics
|December 7, 2020
PubMed
Summary

A new, automatic calibration method for dual energy radiography (DER) simplifies tissue imaging. This technique accurately separates bone and soft tissue, improving spine visualization and nodule detection without expert calibration.

Keywords:
calibrationdual energyquantitative radiographyx-ray

More Related Videos

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.5K
Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure
10:22

Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure

Published on: February 12, 2018

11.0K

Related Experiment Videos

Last Updated: Nov 27, 2025

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

11.5K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.5K
Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure
10:22

Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure

Published on: February 12, 2018

11.0K

Area of Science:

  • Medical Imaging Physics
  • Radiographic Technology
  • Biomedical Engineering

Background:

  • Dual energy radiography (DER) enables separate imaging of soft-tissue and bony structures.
  • Current DER methods rely on manual tuning or calibration-based decomposition.
  • Optimizing the calibration process is crucial for accurate DER.

Purpose of the Study:

  • To investigate the optimal method for calibrating dual energy radiography.
  • To develop an automatic calibration protocol for improved DER.
  • To assess the impact of phantom materials and size on calibration accuracy.

Main Methods:

  • Simulations were used to optimize the calibration protocol for DER.
  • Various soft-tissue (water, PMMA, A-150) and bone-equivalent (Teflon, B-100, aluminum) materials were evaluated.
  • Four optimized calibration designs were tested on a realistic thorax phantom using the NOVA FA X-ray system.

Main Results:

  • A simple, inexpensive calibration phantom with relaxed placement requirements yielded accurate results.
  • The method achieved appropriate separation of the spine for densitometry.
  • Nodules as small as 6 mm were identified, addressing a known limitation in radiography.

Conclusions:

  • The proposed DER calibration method is fully automatic, eliminating the need for specialized technician expertise.
  • This technique provides quantitative mass thickness values, enabling precise planar studies.
  • The method moves beyond relative comparisons to offer absolute quantitative measurements in radiography.