A New Fractional Particle Swarm Optimization with Entropy Diversity Based Velocity for Reactive Power Planning

Muhammad Waleed Khan1, Yasir Muhammad1, Muhammad Asif Zahoor Raja1,2

  • 1Department of Electrical and Computer Engineering, COMSATS University Islamabad, Attock 22060, Pakistan.

Related Concept Videos

The Swing Equation01:21

The Swing Equation

The Swing Equation is a fundamental tool in power system dynamics, especially for analyzing the behavior of generating units like three-phase synchronous generators. This equation emerges from applying Newton's second law to the rotor of a generator, encompassing factors such as inertia, angular acceleration, and the interplay between mechanical and electrical torques.
In a steady-state operation, the mechanical torque (Τm) supplied to the generator is balanced by the electrical torque (Τe)...
971
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
442
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
352
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
399
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
294
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
248