A novel fault tolerant control approach based on backstepping controller for a five phase induction motor drive:

Mahmoud A Mossa1, Hamdi Echeikh2

  • 1Electrical Engineering Department, Faculty of Engineering, Minia University, Minia 61111, Egypt.

ISA Transactions
|December 8, 2020
PubMed

Related Concept Videos

Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
248
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
516
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
414
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
399
PI Controller: Design01:24

PI Controller: Design

Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
861
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
405