Related Experiment Video
Updated: Nov 26, 2025

08:42
Real-time Visualization and Analysis of Chondrocyte Injury Due to Mechanical Loading in Fully Intact Murine Cartilage Explants
Published on: January 7, 2019
7.0K
Detecting Articular Cartilage and Meniscus Deformation Effects Using Magnetization Transfer Ultrashort Echo Time
Saeed Jerban1, Akhil Kasibhatla1, Yajun Ma1
1Department of Radiology, University of California, San Diego, CA, USA.
Cartilage
|December 8, 2020
Summary
Ultrashort echo time magnetic resonance imaging with magnetization transfer (UTE-MT) shows changes in knee cartilage and meniscus under mechanical load in young donors. Elderly donors exhibited no significant changes, suggesting UTE-MT can differentiate knee joint health.
Area of Science:
- Biomedical Engineering
- Radiology
- Orthopedics
Background:
- Ultrashort echo time (UTE) MRI sequences enhance imaging of musculoskeletal (MSK) tissues with short T2 relaxation times.
- UTE MRI combined with magnetization transfer modeling (UTE-MT) provides robust assessment of MSK tissues.
Purpose of the Study:
- To investigate the variation of UTE-MT measures in tibiofemoral cartilage and meniscus under mechanical loading in cadaveric knee joints.
- To assess the impact of mechanical loading on UTE-MT parameters in young versus elderly knee joints.
Main Methods:
- Fourteen cadaveric knee joints (8 young, 6 elderly) were scanned using UTE-MT sequences at 3-T under three loading conditions (0 N, 300 N, 500 N).
- Macromolecular proton fraction (MMF) was calculated from UTE-MT modeling for various knee regions (meniscus, articular cartilage).
- Statistical analysis (Wilcoxon rank sum test) was performed to compare MRI data between loading conditions and age groups.
Main Results:
- In young donors, MMF increased significantly in the meniscus and loaded articular cartilage regions with increased load (300 N to 500 N).
- MMF decreased significantly in unloaded articular cartilage regions in young donors.
- Elderly donors showed no significant changes in MMF across loading conditions.
Conclusions:
- UTE-MT modeling combined with knee loading can differentiate between normal and potentially abnormal knee joints.
- Tissue deformation effects under load appear more pronounced and uniform in younger knee joints compared to elderly ones.