Dynamic conformal arcs-based single-isocenter VMAT planning technique for radiosurgery of multiple brain metastases
Damodar Pokhrel1, Allison N Palmiero1, Mark E Bernard1
1Department of Radiation Medicine, University of Kentucky, Lexington KY.
Abstract:
Multiple small beamlets in the delivery of highly modulated single-isocenter HyperArc VMAT plan can lead to dose delivery errors associated with small-field dosimetry, which can be a major concern for stereotactic radiosurgery for multiple brain lesions. Herein, we describe and compare a clinically valuable dynamic conformal arc (DCA)-based VMAT (DCA-VMAT) approach for stereotactic radiosurgery of multiple brain lesions using flattening filter free beams to minimize this effect. Original single-isocenter HyperArc style VMAT and DCA-VMAT plans were created on 7 patients with 2 to 8 brain lesions (total 35 lesions) for 10 MV- flattening filter free beam. 20 Gy was prescribed to each lesion. For identical planning criteria, DCA-VMAT utilizes user-controlled field aperture shaper before VMAT optimization. Plans were evaluated for conformity and target coverage, low- and intermediate dose spillages to brain volume that received more than 30% (V30%) and 50% (V50%) of prescription dose. Additionally, mean brain dose, V8, V12 and maximal dose to adjacent organs-at-risk (OAR) including hippocampi were reported. Total monitor units, beam modulation factor, treatment delivery efficiency, and accuracy were recorded. Comparing with original VMAT, DCA-VMAT plans provided similar tumor dose, target coverage and conformity, yet tighter radio-surgical dose distribution with lower dose to normal brain V30% (p = 0.009), V50% (p = 0.05) and other OAR including lower dose to hippocampi. Lower total number of monitor units and smaller beam modulation factor reduced beam on time by 2.82 min (p < 0.001), on average (maximum up to 3.8 min). Beam delivery accuracy was improved by 8%, on average (p < 0.001) and maximum up to 13% in some cases for DCA-VMAT plans. This novel DCA-VMAT approach provided excellent plan quality, reduced dose to normal brain, and other OAR while significantly reducing beam-on time for radiosurgery of multiple brain lesions-improving patient compliance and clinic workflow. It also provided less MLC modulation through the targets-potentially minimizing small field dosimetry errors as demonstrated by quality assurance results. Incorporating DCA-based VMAT optimization in HyperArc module for radiosurgery of multiple brain lesions merits future investigation.
More Related Videos
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022