Ultrasonographic Assessment During Cardiopulmonary Resuscitation
Published on: October 24, 2020
Cardiopulmonary Resuscitation Feedback: A Comparison of Device-Measured and Self-Assessed Chest Compression Quality
Background:
High-quality cardiopulmonary resuscitation is the foundation of cardiac arrest care. Guidelines specify chest compression depth, recoil, and rate, but providers often fail to achieve these targets. Furthermore, providers are largely unable assess the quality of their own or other peoples' chest compressions. Chest compression feedback devices can improve chest compression quality; their use is endorsed internationally, but they remain largely absent in clinical care. This article analyzes preclinical data collected during a quality improvement project. It describes provider demographics and perceptions about their chest compression quality and correlates them to measured chest compression quality, compares clinician perception of chest compressions to objective measures, and describes the effect of feedback on compression quality.
Methods:
Clinicians were recruited from 2 metropolitan emergency departments. A questionnaire was used to assess participants' levels of training and experience. A before-and-after assessment of chest compression quality was performed using a Laerdal CPRmeter 2 and a CPR mannequin. Pretest measures of chest compression quality were made by covering the device screen thereby blinding providers to feedback; repeat measures were then collected from the same participants but unblinded to feedback. Provider charecteristic were collected by survey. Correlations between blinded chest compression quality and provider charecteristics; the reliability of providers estimated compared to measured quality; and the effects of feedback on chest compression quality were assessed using Pearsons correlations, Cohens κ, and paired t testing.
Results:
84 participants were assessed. The mean years of certification were 11.74. Ninty-five percent of the providers self-assessed as more experienced than novice and 81% reported performing cardiopulmonary resuscitation at least occasionally. The frequency of performing chest compressions was correlated with self-assessed skill (r = 0.58, P < .001). However, self-assessed skill was only weakly correlated with chest compression quality (r = 0.29, P = .01) and not at all with the frequency of performing chest compressions or years of certification. There was no agreement between self-assessed and device-measured chest compression depth (κ = -0.10, P = 0.11), recoil (κ = -0.14, P = .03), or rate (κ = 0.06, P =.30). The overall quality of compressions improved by 16.9%; the percentage of chest compressions achieving target depth by 3.58%; recoil by 22.82%; and rate by 23.66% with feedback. A total of 97.6% of the staff rated chest compression feedback helpful.
Conclusions:
Our findings suggest that participants' demographics were not correlated with chest compression quality and that providers cannot reliably assess chest compression quality. The data also demonstrate that with minimal training, feedback can significantly improve chest compression quality.
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...