Related Experiment Video
Updated: Nov 26, 2025

Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
Diaphragm Ultrasound in Weaning From Mechanical Ventilation
Deepti Kilaru1, Nova Panebianco1, Cameron Baston2
1Department of Emergency Medicine, Perelman School of Medicine, University of Pennsylvania/Perelman School of Medicine, Philadelphia, PA.
Abstract:
A 65-year-old man was admitted to the ICU for septic shock due to pneumonia. He remained on mechanical ventilation for 96 hours. His shock resolved, and he no longer required IV vasopressor therapy. His vital signs included a BP of 105/70 mm Hg, heart rate 85 beats/min, respiratory rate 22 breaths/min, and oxygen saturation 95%. His ventilator settings were volume control/assist control with a positive end-expiratory pressure of 5 and an Fio2 set to 40%. On these setting his blood gas showed an Pao2 of 75 mm Hg. He was following simple commands and had minimal tracheobronchial secretions. He was placed on a spontaneous breathing trial with a spontaneous mode of ventilation and pressure support of 7/5. He remained hemodynamically stable and showed no distress through the procedure, so he was extubated to 6 L oxygen by nasal cannula. Eighteen hours later, the patient was found to have increased work of breathing, with use of accessory respiratory muscles. A blood gas showed an elevated level of CO2, so the patient was reintubated. After intubation, the patient again appeared comfortable on minimal ventilator settings. Chest radiography before reintubation showed no new parenchymal process, but an elevated left diaphragm. After a thorough workup, it was determined that diaphragmatic weakness was the most likely reason for respiratory failure. The team questioned whether there was a way to have detected this before extubation.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:

