Effects of left ventricular assist device on pulmonary functions and pulmonary hemodynamics: A meta-analysis.
Waqas Ullah1, Casey Meizinger1, Zain Ali1
1Department of Internal Medicine, Abington Jefferson Health, Abington, PA 19001, United States.
Background:
Given current evidence, the effect of left ventricular assist device (LVAD) implantation on pulmonary function tests remains controversial.
Aim:
To better understand the factors contributing to the changes seen on pulmonary function testing and the correlation with pulmonary hemodynamics after LVAD implantation.
Methods:
Electronic databases were queried to identify relevant articles. The summary effect size was estimated as a difference of overall means and standard deviation on a random-effects model.
Results:
A total of four studies comprising 219 patients were included. The overall mean forced expiratory volume in one second (FEV1), forced vital capacity (FVC) and diffusion lung capacity of carbon monoxide (DLCO) after LVAD implantation were significantly lower by 0.23 L (95%CI: 0.11-0.34, P = 00002), 0.18 L (95%CI: 0.03-0.34, P = 0.02), and 3.16 mmol/min (95%CI: 2.17-4.14, P < 0.00001), respectively. The net post-LVAD mean value of the cardiac index was significantly higher by 0.49 L/min/m2 (95%CI: 0.31-0.66, P < 0.00001) compared to pre-LVAD value. The pulmonary capillary wedge pressure and pulmonary vascular resistance were significantly reduced after LVAD implantation by 8.56 mmHg (95%CI: 3.78-13.35, P = 0.0004), and 0.83 Woods U (95%CI: 0.11-1.55, P = 0.02), respectively. There was no significant difference observed in the right atrial pressure after LVAD implantation (0.61 mmHg, 95%CI: -2.00 to 3.32, P = 0.65). Overall findings appear to be driven by studies using HeartMateII devices.
Conclusion:
LVAD implantation might be associated with a significant reduction of the spirometric measures, including FEV1, FVC, and DLCO, and an overall improvement of pulmonary hemodynamics.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Mitral Stenosis I: Introduction
Heart Failure VI: Adjunct Therapies
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure V: Medical Management
Cardiomyopathy V: Interprofessional Care
Heart Failure II: Pathophysiology