Related Experiment Video
Updated: Nov 25, 2025

A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Closed-loop insulin delivery in adults with type 1 diabetes in real-life conditions: a 12-week multicentre,
Pierre-Yves Benhamou1, Sylvia Franc2, Yves Reznik3
1Department of Endocrinology, Grenoble University Hospital, INSERM U1055, Grenoble Alpes University, Grenoble, France.
Background:
Closed-loop insulin delivery systems are expected to become a standard treatment for patients with type 1 diabetes. We aimed to assess whether the Diabeloop Generation 1 (DBLG1) hybrid closed-loop artificial pancreas system improved glucose control compared with sensor-assisted pump therapy.
Methods:
In this multicentre, open-label, randomised, crossover trial, we recruited adults (aged ≥18 years) with at least a 2 year history of type 1 diabetes, who had been treated with external insulin pump therapy for at least 6 months, had glycated haemoglobin (HbA1c) of 10% or less (86 mmol/mol), and preserved hypoglycaemia awareness. After a 2-week run-in period, patients were randomly assigned (1:1) with a web-based system in randomly permuted blocks of two, to receive insulin via the hybrid closed-loop system (DBLG1; using a machine-learning-based algorithm) or sensor-assisted pump therapy over 12 weeks of free living, followed by an 8-week washout period and then the other intervention for 12 weeks. The primary outcome was the proportion of time that the sensor glucose concentration was within the target range (3·9-10·0 mmol/L) during the 12 week study period. Efficacy analyses were done in the modified intention-to-treat population, which included all randomly assigned patients who completed both 12 week treatment periods. Safety analyses were done in all patients who were exposed to either of the two treatments at least once during the study. This trial is registered with ClinicalTrials.gov, number NCT02987556.
Findings:
Between March 3, 2017, and June 19, 2017, 71 patients were screened, and 68 eligible patients were randomly assigned to the DBLG1 group (n=33) or the sensor-assisted pump therapy group (n=35), of whom five dropped out in the washout period (n=1 pregnancy; n=4 withdrew consent). 63 patients completed both 12 week treatment periods and were included in the modified intention-to-treat analysis. The proportion of time that the glucose concentration was within the target range was significantly higher in the DBLG1 group (68·5% [SD 9·4] than the sensor-assisted pump group (59·4% [10·2]; mean difference 9·2% [95% CI 6·4 to 11·9]; p<0·0001). Five severe hypoglycaemic episodes occurred in the DBLG1 group and three episodes occurred in the sensor-assisted pump therapy group, which were associated with hardware malfunctions or human error.
Interpretation:
The DBLG1 system improves glucose control compared with sensor-assisted insulin pumps. This finding supports the use of closed-loop technology combined with appropriate health care organisation in adults with type 1 diabetes.
Funding:
French Innovation Fund, Diabeloop.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...

