Fully-automated production of [68Ga]Ga-FAPI-46 for clinical application
Sarah Spreckelmeyer1, Matthias Balzer2, Simon Poetzsch2
1Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Nuclear Medicine, Augustenburger Platz 1, 13353, Berlin, Germany. sarah.spreckelmeyer@charite.de.
Automated synthesis of [68Ga]Ga-FAPI-46, a fibroblast activation protein imaging tracer, was successfully achieved on two synthesis modules. This advancement ensures the tracer is readily available for multi-dose clinical applications.
Area of Science:
- Radiochemistry
- Nuclear Medicine
- Pharmaceutical Sciences
Background:
- [68Ga]Ga-FAPI-46 is a positron emission tomography tracer for fibroblast activation protein (FAP) detection.
- Current synthesis methods for [68Ga]Ga-FAPI-46 are manual, limiting clinical accessibility.
- Automating the synthesis is crucial for widespread clinical use.
Purpose of the Study:
- To evaluate the automated synthesis of [68Ga]Ga-FAPI-46.
- To assess the feasibility of using two commercial synthesis modules for automated production.
- To ensure the tracer's availability for clinical applications.
Main Methods:
- Automated synthesis of [68Ga]Ga-FAPI-46 on Modular Lab PharmTracer (MLPT) and Modular Lab eazy (ML eazy).
- Optimization of precursor amounts (10-50 μg) and use of customized synthesis templates and cassettes.
- Quality control testing including sterility, stability, and radiochemical purity.
Main Results:
- Optimal synthesis yielded [68Ga]Ga-FAPI-46 with 50 μg of FAPI-46 precursor for multi-dose application.
- Automated synthesis was successfully performed on both MLPT and ML eazy modules.
- All quality control parameters met European Pharmacopoeia standards.
Conclusions:
- Fully automated synthesis of [68Ga]Ga-FAPI-46 is feasible on MLPT and ML eazy.
- The automated process makes [68Ga]Ga-FAPI-46 readily available for multi-dose clinical use.
- This automation facilitates broader clinical application of FAP-targeted PET imaging.