Related Experiment Video
Updated: Nov 25, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors
Abdella M Ahmed1,2, Andrew Chacon1,2, Harley Rutherford1,2
1Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW, 2234, Australia.
Abstract:
The purpose of this work is to develop a validated Geant4 simulation model of a whole-body prototype PET scanner constructed from the four-layer depth-of-interaction detectors developed at the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Japan. The simulation model emulates the behaviour of the unique depth of interaction sensing capability of the scanner without needing to directly simulate optical photon transport in the scintillator and photodetector modules. The model was validated by evaluating and comparing performance metrics from the NEMA NU 2-2012 protocol on both the simulated and physical scanner, including spatial resolution, sensitivity, scatter fraction, noise equivalent count rates and image quality. The results show that the average sensitivities of the scanner in the field-of-view were 5.9 cps kBq-1 and 6.0 cps kBq-1 for experiment and simulation, respectively. The average spatial resolutions measured for point sources placed at several radial offsets were 5.2± 0.7 mm and 5.0± 0.8 mm FWHM for experiment and simulation, respectively. The peak NECR was 22.9 kcps at 7.4 kBq ml-1 for the experiment, while the NECR obtained via simulation was 23.3 kcps at the same activity. The scatter fractions were 44% and 41.3% for the experiment and simulation, respectively. Contrast recovery estimates performed in different regions of a simulated image quality phantom matched the experimental results with an average error of -8.7% and +3.4% for hot and cold lesions, respectively. The results demonstrate that the developed Geant4 model reliably reproduces the key NEMA NU 2-2012 performance metrics evaluated on the prototype PET scanner. A simplified version of the model is included as an advanced example in Geant4 version 10.5.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

