Study of corneal biomechanical properties in patients with childhood glaucoma
Sara Garcia Caride1, Lucia Perucho González1, Federico Sáenz Francés1
1Ophthalmology, Clinico San Carlos Hospital, Profesor Martín Lagos Street, Madrid, ES 28040, Spain.
Aim:
To study of corneal biomechanical properties and intraocular pressure (IOP) measured with Corvis Scheimpflug Technology (ST) in patients with childhood glaucoma (CG).
Methods:
Cross-sectional study in which 89 eyes were included 56 of them with CG. Only one eye per patient was included. The following variables were obtained from the clinical history and the ophthalmological examination: age, sex, IOP, number of surgeries, and the cup/disc ratio (CDR). The following parameters were recorded using Corvis ST: corrected by biomechanics IOP (bIOP), not corrected IOP (nctIOP), central corneal thickness (CCT), maximum concavity [radius, peak distance (PD) and deformation amplitude], applanation 1 and 2 (length and velocity). The mean age was 23±14.55 and 33±19.5 years old for the control group and CG group, respectively. Totally 36 were males and 53 were females. In the CG group, 7 patients were controlled only with medical treatment. Sixteen had at least one previous goniotomy, 19 had at least one trabeculectomy, and 11 had an Ahmed implant.
Results:
A significant and positive intraclass correlation coefficient was found between Goldman IOP and the IOP measured by Corvis in both groups. No differences were found between the IOP measured with Corvis and Goldman using a student t-test. Regarding biomechanical parameters, there were differences in the applanation length 2 (A-L2), in the applanation velocity 2 (A-V2) and in the PD. By sex, only the applanation length 1 (A-L1) was found to be different in control group. A positive and significant Pearson correlation was found between CDR and the A-L1.
Conclusion:
Corneal biomechanical properties have shown differences between CG and healthy subjects and also between men and women.
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...