Forecast Model Update Based on a Real-Time Data Processing Lambda Architecture for Estimating Partial Discharges in
Fabio Henrique Pereira1,2,3, Francisco Elânio Bezerra2, Diego Oliva1
1Informatics and Knowledge Management Graduate Program, Nove de Julho University-UNINOVE, São Paulo 01525-000, Brazil.
Abstract:
The prediction of partial discharges in hydrogenerators depends on data collected by sensors and prediction models based on artificial intelligence. However, forecasting models are trained with a set of historical data that is not automatically updated due to the high cost to collect sensors' data and insufficient real-time data analysis. This article proposes a method to update the forecasting model, aiming to improve its accuracy. The method is based on a distributed data platform with the lambda architecture, which combines real-time and batch processing techniques. The results show that the proposed system enables real-time updates to be made to the forecasting model, allowing partial discharge forecasts to be improved with each update with increasing accuracy.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Related Concept Videos
Design Example: Creating a Hydraulic Model of a Dam Spillway
Fast Decoupled and DC Powerflow
Typical Model Studies
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Control of Power Flow