Related Experiment Video
Updated: Nov 24, 2025

Application of Indocyanine Green Fluorescence Imaging Technology in Laparoscopic Duodenum-Preserving Pancreatic Head Resection
Published on: November 21, 2025
Indocyanine Green Fluorescence Angiography after Full-thickness Bowel Resection for Rectosigmoid Endometriosis-A
Diego Raimondo1, Manuela Maletta2, Giulia Borghese2
1Division of Gynaecology and Human Reproduction Physiopathology, Department of Medical and Surgical Sciences (DIMEC), IRCCS Azienda Ospedaliero-Universitaria di Bologna, S. Orsola Hospital, University of Bologna, Bologna, Italy (all authors)..
Study Objective:
To evaluate feasibility of near-infrared (NIR)-indocyanine green (ICG) imaging for bowel vascularization assessment after full-thickness bowel resection for rectosigmoid endometriosis (RSE).
Design:
This is a prospective, single-center, preliminary study on consecutive patients who were symptomatic submitted to discoid or segmental resection for RSE and NIR-ICG evaluation for vascular assessment of the anastomotic line from May 2018 to January 2020.
Setting:
Tertiary university hospital.
Patients:
Thirty-two women with RSE meeting eligibility criteria were included for study analysis.
Interventions:
NIR-ICG evaluation of anastomotic line vascularization after RSE removal.
Measurements And Main Results:
Fluorescence degree of the anastomotic line was assessed with a 0 to 2 Likert scale, as follows: 0 or "absent" (no fluorescence observed), 1 or "irregular" (not uniform distribution or weak fluorescence), and 2 or "regular" (uniform distribution of fluorescence and similar to the proximal colon). In all the patients included in the study (100%), NIR-ICG imaging allowed the evaluation of fluorescence degree of the anastomotic line. No adverse reaction related to ICG use was recorded. The protocol did not greatly lengthen operating time (median, 4 [range, 3-5] minutes). Excellent interoperator agreement was observed. Most of the patients (31 of 32, 96.9%) showed regular fluorescence on the anastomotic line; in 1 patient with irregular fluorescence at NIR-ICG after discoid excision, the anastomotic suture was reinforced through interrupted stitches. We had 1 case of anastomotic leakage after segmental resection with intraoperative good fluorescence at NIR-ICG evaluation.
Conclusion:
NIR-ICG imaging for anastomotic perfusion assessment after discoid or segmental resection for RSE seems to be a feasible, safe, and reproducible method.
More Related Videos
04:01Indocyanine Green-Guided Intraoperative Imaging to Facilitate Video-Assisted Retroperitoneal Debridement for Treating Acute Necrotizing Pancreatitis
Published on: September 8, 2022
03:27The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy