Related Experiment Video
Updated: Nov 24, 2025

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
Quoc Khanh Nguyen1,2, Seungman Kim1, Seong-Heum Han1
1Department of Ultra-Precision Machines and Systems, Korea Institute of Machinery and Materials, Daejeon 34103, Korea.
Abstract:
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
Related Concept Videos
Common Leveling Mistakes and Errors
Distance Corrections
Errors in Global Positioning System
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...