Attenuation correction in single-photon emission computed tomography for NURBS-based cardiac-torso phantom using
Hossein Rajabi1, Hadi Taleshi Ahangari2, Iraj Mohammadi3,4
1Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
Abstract:
Single photon emission tomography is widely used to detect photons emitted from the patient. Some of these emitted photons suffer from scattering and absorption because of the attenuation occurred through their path in patient's body. Therefore, the attenuation is the most important problem in single-photon emission computed tomography (SPECT) imaging. Some of the radioisotopes emit gamma rays in different energy levels, and consequently, they have different counts and attenuation coefficients. Calculation of the parameters used in the attenuation equation N out=αNin = e- μ l Nin by mathematical methods is useful for the attenuation correction. Nurbs-based cardiac-torso (NCAT) phantom with an adequate attenuation coefficient and activity distribution is used in this study. Simulations were done using SimSET in 20-70 and 20-167 keV. A total of 128 projections were acquired over 360°. The corrected and reference images were compared using a universal image quality index (UIQI). The simulation repeated using NCAT phantom by SimSET. In the first group, no attenuation correction was used, but the Zubal coefficients were used for attenuation correction in the second image group. After the image reconstruction, a comparison between image groups was done using optimized UIQI to determine the quality of used reconstruction methods. Similarities of images were investigated by considering the average sinogram for every block size. The results showed that the proposed method improved the image quality. This study showed that simulation studies are useful tools in the investigation of nuclear medicine researches. We produced a nonattenuated model using Monte Carlo simulation method and compared it with an attenuated model. The proposed reconstruction method improved image resolution and contrast. Regional and general similarities of images could be determined, respectively, from acquired UIQI of small and large block sizes. Resulted curves from both small and large block sizes showed a good similarity between reconstructed and ideal images.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET