Baseline correction method based on improved asymmetrically reweighted penalized least squares for the Raman spectrum
Abstract:
We present a baseline correction method based on improved asymmetrically reweighted penalized least squares (IarPLS) for the Raman spectrum. This method utilizes a new S-type function to reduce the risk of baseline overestimation and speed up the reweighting process. Simulated spectra with different levels of noise and measured spectra with strong fluorescence background from different samples are used to validate the performance of the proposed algorithm. Considering the drawbacks of the weighting rules for the asymmetrically reweighted penalized least squares (arPLS) method, we adapt an inverse square root unit (ISRU) function, which performs well in baseline correction. Compared with previous penalized least squares methods, such as asymmetric least squares, adaptive iteratively reweighted penalized least squares, and arPLS, experiments with the simulated Raman spectra have confirmed that the proposed method yields better outcomes. Experiments with the measured Raman spectra show that the IarPLS method can improve real Raman spectra within 20 ms. The results show that the proposed method can be successfully applied to the practical Raman spectrum as a strong basis for quantitative analysis.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR Spectrometers: Resolution and Error Correction
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...