Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Biological Effects of Radiation02:59

Biological Effects of Radiation

16.8K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
16.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-Throughput MicroED for Probing Ion Channel Dynamics.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2025
Same author

Ligand Screening and Discovery Using Cocktail Soaking and Automated Microcrystal Electron Diffraction.

ChemMedChem·2025
Same author

Publisher Correction: Energy filtering enables macromolecular MicroED data at sub-atomic resolution.

Nature communications·2025
Same author

Characterization of energy filtering slit widths for MicroED data collection.

bioRxiv : the preprint server for biology·2025
Same author

Energy filtering enables macromolecular MicroED data at sub-atomic resolution.

Nature communications·2025
Same author

Ligand Screening and Discovery using Cocktail Soaking and Automated MicroED.

bioRxiv : the preprint server for biology·2025

Related Experiment Video

Updated: Nov 24, 2025

Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
11:24

Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation

Published on: July 3, 2015

11.3K

Low-Dose Data Collection and Radiation Damage in MicroED.

Johan Hattne1

  • 1Department of Biological Chemistry, David Geffen School of Medicine, Howard Hughes Medical Institute, University of California, Los Angeles, CA, USA. hattne@ucla.edu.

Methods in Molecular Biology (Clifton, N.J.)
|December 28, 2020
PubMed
Summary

Microcrystal electron diffraction (MicroED) determines structures using electron beams, but radiation damage limits data. This study optimizes MicroED data collection by balancing electron dose and detector sensitivity for better crystal lattice analysis.

Keywords:
Cryo-EMData collectionDoseMicroEDRadiation damage

More Related Videos

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
08:23

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes

Published on: December 25, 2021

5.1K
Application of Laser Micro-irradiation for Examination of Single and Double Strand Break Repair in Mammalian Cells
08:18

Application of Laser Micro-irradiation for Examination of Single and Double Strand Break Repair in Mammalian Cells

Published on: September 5, 2017

10.0K

Related Experiment Videos

Last Updated: Nov 24, 2025

Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
11:24

Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation

Published on: July 3, 2015

11.3K
An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
08:23

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes

Published on: December 25, 2021

5.1K
Application of Laser Micro-irradiation for Examination of Single and Double Strand Break Repair in Mammalian Cells
08:18

Application of Laser Micro-irradiation for Examination of Single and Double Strand Break Repair in Mammalian Cells

Published on: September 5, 2017

10.0K

Area of Science:

  • Crystallography
  • Materials Science
  • Biophysics

Background:

  • Microcrystal electron diffraction (MicroED) is a powerful technique for atomic-resolution structure determination of small crystals.
  • Electron-sample interactions cause radiation damage, altering the crystal during data acquisition and limiting achievable resolution.
  • Cryogenic temperatures and low-dose strategies mitigate damage but can reduce signal-to-noise ratios.

Purpose of the Study:

  • To investigate methods for optimizing MicroED data collection to maximize structural information recovery.
  • To understand the trade-offs between electron dose, crystal damage, and data quality in MicroED.
  • To provide guidance on selecting appropriate experimental parameters for high-quality MicroED datasets.

Main Methods:

  • Analysis of electron-sample interactions and radiation damage mechanisms in MicroED.
  • Evaluation of the impact of varying electron doses on diffraction data quality.
  • Consideration of detector types and their influence on signal detection and noise levels.
  • Optimization strategies balancing dose and signal-to-noise ratio for MicroED experiments.

Main Results:

  • Radiation damage is an inherent limitation in MicroED, necessitating careful dose management.
  • Lower electron doses reduce crystal damage, potentially increasing the measurable lattice volume.
  • Signal recovery from low-dose data is challenged by noise from solvent, disorder, and detector limitations.
  • Optimizing dose and detector choice is crucial for maximizing data quality in MicroED.

Conclusions:

  • Achieving high-quality MicroED data requires a holistic approach considering sample properties, electron dose, and detector technology.
  • Careful optimization of experimental parameters can mitigate radiation damage and improve the accuracy of structure determination.
  • Further research into advanced detectors and dose-reduction strategies will enhance the capabilities of MicroED.