Related Experiment Video
Updated: Nov 24, 2025

Biosensor for Detection of Antibiotic Resistant Staphylococcus Bacteria
Published on: May 8, 2013
Staphylococcal bacterial contamination of portable electronic devices in a large veterinary hospital
G Vinall1,2, T Cogan1, A Jeffery1
1Bristol Veterinary School, University of Bristol, Langford Bristol, BS40 5DU, UK.
Background:
Portable electronic devices are used regularly within the veterinary and medical environments. Use of these in clinical areas may predispose them to bacterial contamination and they could act as fomites, transmitting infection between clinicians and patients.
Aim:
To determine the prevalence, origin and nature of Staphylococcal bacterial contamination on the surface of portable electronic devices used in a large small animal hospital.
Materials And Methods:
Staff were surveyed on the frequency of portable electronic device use and device-cleaning routines. Portable electronic devices were swabbed for staphylococcus species. Cultured cocci were tested for antimicrobial resistance and identified at the species level to help determine the likely source (human or animal).
Findings:
Forty one of 48 (85%) of staff used a portable electronic device every day within the hospital. Useable swabs were obtained from 47 portable electronic devices. Staphylococci were found on 68% of portable electronic devices. Vancomycin and Oxacillin resistance were seen in 17 of 46 (37%) and 1 of 46 (2%) isolated colonies respectively, including four vancomycin resistant, coagulase-positive staphylococci. 44% of staff never cleaned their device.
Clinical Significance:
Portable electronic devices are commonly used in veterinary hospitals, but few staff routinely disinfect them. The use of disinfectant to reduce colony counts should be implemented when forming protocols for these devices in the hospital. The majority of staphylococci found were of likely human origin. It is suggested that contamination is therefore more likely to be originating from staff rather than patients.
More Related Videos
09:59Application of the Intelligent High-Throughput Antimicrobial Sensitivity Testing/Phage Screening System and Lar Index of Antimicrobial Resistance
Published on: July 21, 2023
10:04A Zebrafish Embryo Model for In Vivo Visualization and Intravital Analysis of Biomaterial-associated Staphylococcus aureus Infection
Published on: January 7, 2019
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.