Related Experiment Video
Updated: Nov 23, 2025

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Covalent coupling fabrication of microporous organic network bonded capillary columns for gas chromatographic
Xue Li1, Yuan-Yuan Cui2, Cheng-Xiong Yang2
1State Key Laboratory of Component-based Chinese Medicine, Tianjin State Key Laboratory of Modern Chinese Medicine & Tianjin Key Laboratory of TCM Chemistry and Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, 301617, China.
Abstract:
Microporous organic networks (MONs) have shown great promise in separation science recently. Exploring novel, simple and convenient strategy to fabricate MONs coated capillary columns for gas chromatography (GC) still remains challenging but desirable for the development of MONs in chromatographic separation. To extend the potential application of MONs in separation science and to further develop novel method for the fabrication of MONs-based capillary columns, here we demonstrate a novel covalent coupling strategy to fabricate uniform MONs bonded capillary columns for GC separation of position isomers and hydrocarbons. The bare capillary column was firstly modified with (3-bromopropyl)trimethoxysilane to provide bromine sites for coupling with alkynyl monomers. The amino- and hydroxyl-functionalized MONs (MON-NH2 and MON-OH) were then directly grown onto the inner wall of the brominated capillary columns via the covalent coupling between bromine and alkynyl groups. The uniform MON-NH2 and MON-OH bonded capillary columns were obtained and showed good resolution for GC separation of dichlorobenzene, chlorotoluene, bromotoluene, and propylbenzene position isomers and many other hydrocarbons including linear alkanes, alkylbenzenes, pinene isomers, cyclohexane and benzene, ketones and aldehydes. The MONs bonded capillary columns also owned good lifetime and precision for dichlorobenzene isomers with the relative standard deviations (RSDs) of 0.2-0.3%, 1.2-2.1%, and 1.7-2.5% for retention time, peak height and peak area, respectively. In addition, the fabricated MON-NH2 and MON-OH bonded capillary columns offered better resolution than commercial InertCap-1, InertCap-5, InertCap-1701 and InertCap-WAX capillary columns for the separation of chlorotoluene and bromotoluene position isomers. These results revealed the feasibility of covalent coupling strategy to fabricate MONs-based stationary phases in GC, highlighting the potential of MONs in separation science.
Related Concept Videos
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process

