Technique failure in remote patient monitoring program in patients undergoing automated peritoneal dialysis: A

Leyder Corzo1, Martin Wilkie2, Jasmin I Vesga3

  • 1Renal Therapy Services, Instituto Nacional del Riñón, Bogotá, Colombia.

Abstract

Related Concept Videos

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
230
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
316
Peritoneal Dialysis III: Nursing Management01:25

Peritoneal Dialysis III: Nursing Management

Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
347
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
886
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis01:30

Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis

Patients with end-stage renal disease (ESRD) or those experiencing drug overdose often require extracorporeal methods to eliminate accumulated drugs and metabolites. Hemoperfusion, hemofiltration, and dialysis are the primary techniques to rapidly remove harmful substances without disrupting the patient's fluid and electrolyte balance. For those with compromised renal function, dosage adjustments of concurrent medications may be necessary during extracorporeal drug removal.Dialysis is a process...
122
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
1.2K