Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
The true nature of P wave dispersion
Jacek Marcin Zawadzki1, Katarzyna Zimmer2, Wojciech Przywara3
1Department of Cardiology, Klodzko County Hospital, Poland.
Background:
The electrophysiological activity of the heart is recorded and presented in form of electrocardiography (ECG). In 1998, the concept of P wave dispersion as the risk factor for atrial fibrillation (AF) recurrence was introduced. It was calculated as the difference between the longest and the shortest P wave.
Objectives:
To prove that the P wave dispersion is an artifact of low accuracy in P wave measurement.
Material And Methods:
The study included 104 patients (48 women, 56 men), aged 63 ±14 years, undergoing various electrophysiological procedures. The P wave was measured twice - firstly at the paper speed of 50 mm/s, enhancement ×8 (standard - imprecise), and secondly at 200 mm/s, ×64-256 (precise).
Results:
The imprecise measurement method resulted in different duration of all P wave parameters in comparison with precise measurement. The longest P wave duration (Pmax) measured imprecisely was 105.1 ±22.1, the Pmax measured precisely was 134.0 ±21.3 (p < 0.001). The P dispersion measured imprecisely was 44.1 ±16.8 and the P dispersion measured precisely was 2.8 ±3.4 (p < 0.0001). The correlation between imprecise Pmax and imprecise Pmin was r = 0.664 (p < 0.05). The correlation between imprecise Pmax and imprecise P wave dispersion was r = 0.612 (p < 0.05). The correlation between precise Pmax and Pmin was almost 1.0 (r = 0.987, p < 0.05).
Conclusions:
The P wave dispersion does not exist. The measurements of the P wave have to be precise to assure the highest scientific and medical sincerity. The highest clinical value is related to the P wave duration.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Intensity Of Electromagnetic Waves
Propagation of Waves
Consider a scenario where a wave propagates from a string of low linear mass density to a string of high linear mass density. In such a case, the reflected wave is out of phase with respect to the incident wave, however the...
Energy Carried By Electromagnetic Waves
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Standing Electromagnetic Waves
Suppose a sheet of a perfect conductor is placed in the yz-plane, and a linearly polarized electromagnetic wave traveling in the...
Modes of Standing Waves - I