Korean-specific biokinetic model for iodine in radiological protection
Tae-Eun Kwon1,2, Yoonsun Chung2, Young Woo Jin1
1National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, 01812 Seoul, Republic of Korea.
Abstract:
The International Commission on Radiological Protection (ICRP) recently adopted a detailed biokinetic model for systemic iodine with reference transfer coefficients based on typical worldwide dietary intakes of stable iodine. The regional data provided demonstrate that the ICRP reference thyroidal biokinetics may differ substantially across regions with atypically low or high dietary intakes of stable iodine. Importantly, the design of the ICRP model facilitates modifications of reference thyroidal kinetics based on regional dietary iodine intake. The present study extended the ICRP model to the South Korean population, whose dietary iodine intake is much higher than the global mean. The following three transfer coefficients were selected as targets for Korean-specific values: thyroidal uptake rate (λ1), hormonal secretion rate (λ4) and leakage rate of thyroidal organic iodine as inorganic iodide (λ5). The Korean-specific values forλ1,λ4andλ5were determined to be 4.48, 0.0086 and 0.0171 d-1, respectively, to yield the measurements of thyroidal iodine and physiological status of Korean adults. The determinedλ1andλ5values differed noticeably from the ICRP values, whereas theλ4value was comparable to that of the ICRP. Compared with the ICRP reference model, the Korean model, in which the Korean-specific transfer coefficients were adopted, predicted noticeably lower thyroidal uptake and faster decrease of thyroidal iodine. In addition, the predicted cumulative activities of radioiodine in the thyroid were substantially lower (40-80%) than those predicted by the ICRP model. The Korean model developed in this study demonstrates that the iodine biokinetics for Koreans (i.e. a population with a high iodine consumption) obviously differ from the prediction of the ICRP model. Hence, the Korean model may serve to improve the accuracy of thyroid dose estimation for Koreans and will lead to practical changes in matters concerned with radiological protection.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
10:16Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Physiological Pharmacokinetic Models: Assumption with Protein Binding
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.