Related Experiment Video
Updated: Nov 22, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Retrospective comparison between single reading plus an artificial intelligence algorithm and two-view digital
Axel Graewingholt1, Stephen Duffy2
1Mammographie-Screening-Zentrum, Paderborn, NRW, Germany.
Objective:
To examine the breast cancer detection rate by single reading of an experienced radiologist supported by an artificial intelligence (AI) system, and compare with two-dimensional full-field digital mammography (2D-FFDM) double reading.
Materials And Methods:
Images (3D-tomosynthesis) of 161 biopsy-proven cancers were re-read by the AI algorithm and compared to the results of first human reader, second human reader and consensus following double reading in screening. Detection was assessed in subgroups by tumour type, breast density and grade, and at two operating points, referred to as a lower and a higher sensitivity threshold.
Results:
The AI algorithm method gave similar results to double-reading 2D-FFDM, and the detection rate was significantly higher compared to single-reading 2D-FFDM. At the lower sensitivity threshold, the algorithm was significantly more sensitive than reader A (97.5% vs. 89.4%, p = 0.02), non-significantly more sensitive than reader B (97.5% vs. 94.4%, p = 0.2) and non-significantly less sensitive than the consensus from double reading (97.5% vs. 99.4%, p = 0.2). At the higher sensitivity threshold, the algorithm was significantly more sensitive than reader A (99.4% vs. 89.4%, p < 0.001) and reader B (99.4% vs. 94.4%, p = 0.02) and identical to the consensus sensitivity (99.7% in both cases, p = 1.0). There were no significant differences in the detection capability of the AI system by tumour type, grading and density.
Conclusion:
In this proof of principle study, we show that sensitivity using single reading with a suitable AI algorithm is non-inferior to that of standard of care using 2D mammography with double reading, when tomosynthesis is the primary screening examination.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...