Related Experiment Video
Updated: Nov 22, 2025

Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research
Published on: November 2, 2018
Resolution enhancement and realistic speckle recovery with generative adversarial modeling of micro-optical coherence
Kaicheng Liang1,2, Xinyu Liu3,4,2, Si Chen3
1Bioinformatics Institute, Agency for Science, Technology and Research (ASTAR), Singapore.
Abstract:
A resolution enhancement technique for optical coherence tomography (OCT), based on Generative Adversarial Networks (GANs), was developed and investigated. GANs have been previously used for resolution enhancement of photography and optical microscopy images. We have adapted and improved this technique for OCT image generation. Conditional GANs (cGANs) were trained on a novel set of ultrahigh resolution spectral domain OCT volumes, termed micro-OCT, as the high-resolution ground truth (∼1 μm isotropic resolution). The ground truth was paired with a low-resolution image obtained by synthetically degrading resolution 4x in one of (1-D) or both axial and lateral axes (2-D). Cross-sectional image (B-scan) volumes obtained from in vivo imaging of human labial (lip) tissue and mouse skin were used in separate feasibility experiments. Accuracy of resolution enhancement compared to ground truth was quantified with human perceptual accuracy tests performed by an OCT expert. The GAN loss in the optimization objective, noise injection in both the generator and discriminator models, and multi-scale discrimination were found to be important for achieving realistic speckle appearance in the generated OCT images. The utility of high-resolution speckle recovery was illustrated by an example of micro-OCT imaging of blood vessels in lip tissue. Qualitative examples applying the models to image data from outside of the training data distribution, namely human retina and mouse bladder, were also demonstrated, suggesting potential for cross-domain transferability. This preliminary study suggests that deep learning generative models trained on OCT images from high-performance prototype systems may have potential in enhancing lower resolution data from mainstream/commercial systems, thereby bringing cutting-edge technology to the masses at low cost.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

