Ruiyu Ding1,2, Yi Heng Cheong1,2, Ashiq Ahamed2,3
1College of Engineering, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
Abstract:
This Feature summarizes recent works in paper-based potentiometry and voltammetry in heavy metal determination. Interactions of paper substrates with heavy metals, influence on the sensing response, and modification methods applied to paper substrates to improve the performance of recently developed electrochemical sensors are discussed. Since the rekindling of interest in paper-based analytical devices, methodologies and electrode designs for heavy metal determinations are highlighted. Promising aspects of the use of these sensors for samples containing solids and the increased versatility of the use of paper in analytics offers the possibility of increased acceptance of these low-cost platforms.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
05:35Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Related Concept Videos
Electrodeposition
Electrodeposition can...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
High-Performance Liquid Chromatography: Types of Detectors
Electrogravimetric Analysis: Overview
To test the completeness of the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...