Related Experiment Video
Updated: Nov 21, 2025

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Percutaneous VDD leadless pacer implant post recent bioprosthetic tricuspid valve replacement for infective
Maria Pia Del Corral1, Pedro Covas1, Cynthia Tracy1
1Cardiology Department, Clinical Cardiac Electrophysiology Service, The George Washington University Hospital, Washington, District of Columbia, USA.
Abstract:
In January 2020, the first Medtronic VDD leadless pacemaker Micra AV was approved by FDA to treat patients with advanced AV block, based on the encouraging results from the Micra Atrial tRacking using a Ventricular accELerometer 2 (MARVEL 2). There is reassuring data about safety and short-term outcomes of traditional leadless pacemaker implant after recent surgical tricuspid valve replacement, but only few cases are reported in literature. No data was found regarding AV Micra implant safety and outcomes in patients following bioprosthetic tricuspid valve replacement as of today. Our patient is a 44-year-old gentleman with history of IV drug use who recently underwent tricuspid replacement with bioprosthesis for infective endocarditis complicated by postsurgical heart block, acute kidney insufficiency requiring hemodialysis, persistent bacteremia and candidemia, and progressive failure of the epicardial pacing wires. Given the elevated infective risk, the decision of attempting leadless pacer implant through the bioprosthetic valve was taken and our patient underwent successful Micra AV implant on postoperative day 30. To our knowledge, this is the first AV Micra placement following bioprosthetic tricuspid valve replacement. The uneventful procedure and the encouraging short-term device follow-up results seem to confirm the relative safety of this device in treating advanced atrioventricular conduction disorders in patients at elevated infective risk.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Endocarditis III: Medical Management
Endocarditis I: Introduction
Endocarditis IV: Nursing Management
Endocarditis II: Clinical Features of Infective Endocarditis
Cardiomyopathy V: Interprofessional Care
Mitral Stenosis III: Medical Management