A generalized class of strongly stable and dimension-free T-RPMD integrators

Jorge L Rosa-Raíces1, Jiace Sun1, Nawaf Bou-Rabee2

  • 1Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA.

Related Concept Videos

Region of Convergence01:17

Region of Convergence

The z-transform is a powerful mathematical tool used in the analysis of discrete-time signals and systems. It is a crucial tool in the analysis of discrete-time systems, but its convergence is limited to specific values of the complex variable z. This range of values, known as the Region of Convergence (ROC), is fundamental in determining the behavior and stability of a system or signal. The ROC defines the region in the complex plane where the z-transform converges, which can take various...
724
Integrator and Differentiator01:13

Integrator and Differentiator

Op-amp circuits have significant applications in various fields, including automotive engineering. One such application is cruise control systems in cars, where op-amp circuits are integral for maintaining a constant speed. In these systems, op-amps function as both integrators and differentiators.
An integrator within an op-amp circuit produces an output directly proportional to the integral of the input signal. This is achieved by replacing the feedback resistor in a typical inverting...
1.2K
Pole and System Stability01:24

Pole and System Stability

The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
641
BIBO stability of continuous and discrete -time systems01:24

BIBO stability of continuous and discrete -time systems

System stability is a fundamental concept in signal processing, often assessed using convolution. For a system to be considered bounded-input bounded-output (BIBO) stable, any bounded input signal must produce a bounded output signal. A bounded input signal is one where the modulus does not exceed a certain constant at any point in time.
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
753
Region of Convergence of Laplace Tarnsform01:20

Region of Convergence of Laplace Tarnsform

The Region of Convergence (ROC) is a fundamental concept in signal processing and system analysis, particularly associated with the Laplace transform. The ROC represents an area in the complex plane where the Laplace transform of a given signal converges, determining the transform's applicability and utility.
Consider a decaying exponential signal that begins at a specific time. When deriving its Laplace transform, the time-domain variable is replaced with a complex variable. This...
896
Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
626