Measurements of housing density along transmission lines

H K Florig1, M G Morgan

  • 1Department of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA 15213.

Bioelectromagnetics
|January 1, 1988
PubMed

Related Concept Videos

Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Transmission Line Design Considerations01:23

Transmission Line Design Considerations

Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
Inductance: Single-Phase And Three-Phase Line01:28

Inductance: Single-Phase And Three-Phase Line

Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Capacitance: Single-Phase And Three-Phase Line01:25

Capacitance: Single-Phase And Three-Phase Line

In electrical power systems, understanding the capacitance of transmission lines is fundamental for efficient operation.
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Transmission-Line Differential Equations01:26

Transmission-Line Differential Equations

Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from the...